Detcon SmartWireless� audio-visual alarm stations are easily and economically deployable in both permanent and temporary installations. These devices feature a battery powered audio visual alarm station designed as a wireless cordless system component. They are rated for Class 1; Division 1, Groups C, D hazardous areas and Class I; Division 2, Groups A, B, C, D. Power is provided by a Detcon designed smart battery pack eliminating the requirement for power or signal cables (line power option available). The standard rechargeable battery packs are capable of delivering enough energy for 4-6 hours of continuous operation in a full alarm condition or 5-6 months (no alarm condition). The standard rechargeable battery pack continuously reports its charge level and estimated operating time before recharge or replacement is required. An optional solar charging panel can be used to extend operating time and maintain full battery charge levels for virtually any application. An optional disposable �D� cell battery pack is capable of delivers even longer operating times. Alarm relay options include adjustable set points and latching/non-latching relays. The audible alarm can be configured for acknowledge/silence via operator interface at the SmartWireless CXT Controller. [av_tab_container position='sidebar_tab sidebar_tab_left' boxed='border_tabs' initial='1'] [av_tab title='SW-AV1-DV1' icon_select='no' icon='ue800' font='entypo-fontello'] Detcon SmartWireless� audio-visual alarm stations are easily and economically deployable in both permanent and temporary installations. These devices feature a battery powered audio visual alarm station designed as a wireless cordless system component. They are rated for Class 1; Division 1, Groups C, D hazardous areas. Power is provided by a Detcon designed smart battery pack eliminating the requirement for power or signal cables (line power option available). The standard rechargeable battery packs are capable of delivering enough energy for 5-7 hours of continu- ous operation in a full alarm condition or 5 months (no alarm condition). The standard rechargeable battery pack continuously reports its charge level and estimated operating time before recharge or replacement is required. An optional solar charging panel can be used to extend operating time and maintain full battery charge levels for virtually any application. An optional disposable �D� cell battery pack is capable of delivering 11-13 hours of continuous operation in a full alarm condition or 9 months (no alarm condition). Alarm level 1 is used to turn on an alarm strobe and alarm level 2 is used to turn on an audible warning device. Alarm relay options include adjustable set points and latching/non-latching relays. Alarm level 2 can be configured for acknowledge/silence via operator interface at the SmartWireless CXT Controller. The SmartWireless� alarm stations use Detcon`s proprietary �Self Healing Mesh� technology which operates at 2.4 GHZ and conforms to non licensed radio frequency appliance usage around the world. Wireless network integrity and security is accomplished using direct sequence spread spectrum DSSS programming topology. Wireless applications can be as simple as a single field device communicating with a host display or any number of field devices forming a network of subscribers. Each device in the network is assigned its unique device identification or a UID. Every device in the network can act as a router and repeater for all other devices in the network. This means that subscribers can �hop� through neighboring devices to communicate with each other thereby widening network access points. This unique and innovative technology is designed to create a robust network that automatically routes around congestion and line-of-sight obstacles while improving throughput as subscriber device density increases. [/av_tab] [av_tab title='SW-AV1-DV2' icon_select='no' icon='ue800' font='entypo-fontello'] Detcon SmartWireless� audio-visual alarm stations are easily and economically deployable in both permanent and temporary installations. These devices feature a battery powered audio visual alarm station designed as a wireless cordless system component. They are rated for Class 1; Division 2, Groups B, C, D hazardous areas. Power is provided by a Detcon designed smart battery pack eliminating the requirement for power or signal cables (line power option available). The standard rechargeable battery packs are capable of delivering enough energy for 4-6 hours of continu- ous operation in a full alarm condition or 5 months (no alarm condition). The standard rechargeable battery pack continuously reports its charge level and estimated operating time before recharge or replacement is required. An optional solar charging panel can be used to extend operating time and maintain full battery charge levels for virtually any application. An optional disposable �D� cell battery pack is capable of delivering 9-11 hours of continuous operation in a full alarm condition or 9 months (no alarm condition). Alarm level 1 is used to turn on an alarm strobe and alarm level 2 is used to turn on an audible warning device. Alarm relay options include adjustable set points and latching/non-latching relays. Alarm level 2 can be configured for acknowledge/silence via operator interface at the SmartWireless CXT Controller. The SmartWireless� alarm stations use Detcon`s proprietary �Self Healing Mesh� technology which operates at 2.4 GHZ and conforms to non licensed radio frequency appliance usage around the world. Wireless network integrity and security is accomplished using direct sequence spread spectrum DSSS programming topology. Wireless applications can be as simple as a single field device communicating with a host display or any number of field devices forming a network of subscribers. Each device in the network is assigned its unique device identification or a UID. Every device in the network can act as a router and repeater for all other devices in the network. This means that subscribers can �hop� through neighboring devices to communicate with each other thereby widening network access points. This unique and innovative technology is designed to create a robust network that automatically routes around congestion and line-of-sight obstacles while improving throughput as subscriber device density increases. [/av_tab] [av_tab title='SW-AV2-DV2' icon_select='no' icon='ue800' font='entypo-fontello'] Detcon SmartWireless� audio-visual alarm stations are easily and economically deployable in both permanent and temporary installations. These devices feature a battery powered audio visual alarm station designed as a wireless cordless system component. They are rated for Class 1; Division 2, Groups B, C, D hazardous areas. Power is provided by a Detcon designed smart battery pack eliminating the requirement for power or signal cables (line power option available). The standard rechargeable battery packs are capable of delivering enough energy for 5-7 hours of continu- ous operation in a full alarm condition or 5 months (no alarm condition). The standard rechargeable battery pack continuously reports its charge level and estimated operating time before recharge or replacement is required. An optional solar charging panel can be used to extend operating time and maintain full battery charge levels for virtually any application. An optional disposable �D� cell battery pack is capable of delivering 8-10 hours of continuous operation in a full alarm condition or 9 months (no alarm condition). The visual and audible devices can be configured to turn on for diffent types of gas alarms (i.e. LEL and H2S) in sequence (i.e. LEL turns on visual 1 and horn while H2S turns on visual 2 and horn), or in 3 separate conditions (i.e. alarm level 1, level 2 and level 3). The alarm controlling the audible can be configured for acknowledge/silence via operator interface at the SmartWireless CXT Controller. The SmartWireless� alarm stations use Detcon`s proprietary �Self Healing Mesh� technology which operates at 2.4 GHZ and conforms to non licensed radio frequency appliance usage around the world. Wireless network integrity and security is accomplished using direct sequence spread spectrum DSSS programming topology. Wireless applications can be as simple as a single field device communicating with a host display or any number of field devices forming a network of subscribers. Each device in the network is assigned its unique device identification or a UID. Every device in the network can act as a router and repeater for all other devices in the network. This means that subscribers can �hop� through neighboring devices to communicate with each other thereby widening network access points. This unique and innovative technology is designed to create a robust network that automatically routes around congestion and line-of-sight obstacles while improving throughput as subscriber device density increases. [/av_tab] [/av_tab_container]